The AC30 variable speed series has been designed to provide users with exceptional levels of control, from simple open loop pumps and fans to closed loop process line applications. Its flexible and highly modular design allows a wide range of communication and I/O modules to be easily added as required. The AC30 has been designed with simplicity in mind, but this does not compromise its functionality. Integrated macros for a range of applications and PLC functionality allow more capable users to create sophisticated control that would previously have required a separate PLC. Designed to operate in environmental classes 3C3 and 3C4 for hydrogen sulfide (H2S) as standard (tested at 25 ppm for 1200 hours) and temperatures up to 50°C. The AC30 also utilises a DC link choke to reduce line harmonics and is available with an integrated EMC filter to C2 1st environment as an option.
Note: AC30 power stacks and interchangeable control modules are also available as separate components, offering higher power up to 450 kW, advanced levels of automation control and greater design flexibility - see the "AC30 Series [Power Modules]" and "AC30 Series [Control Modules]" pages in the Recommended Products section for more information.
Markets:
- air conditioning
- Heating
- Cooling
- Ventilation
- Other plumbing
- Marine and offshore
- Air and gas compressors
- Factory automation
- Printing and labelling equipment
- Various industry
- Conversion
- Pulp and paper
- Food and drink
- Wire and cable processing
Features/Benefits:
- Flexibility
- Operation without or without feedback (optional) with encoder feedback module
- Suitable for operation with AC induction motors and permanent magnet servo motors (PMAC)
- Ethernet Modbus TCP/IP as standard
- I/O expansion options
- Support for popular industrial fieldbuses
- Chassis or panel mounting as standard
- Advanced control with Parker Drive Developer (PDD) advanced software tool
- Simplicity
- Easy to configure with Parker Drive Developer (PDQ) software tools
- Multi-language graphical keypad
- Quick start guides
- Removable terminal covers with built-in drive
- Reliability
- Conformal coated for harsh environment protection as standard
- Spring clamp control terminal connections
- Insulated power pack cooling with removable fan
- 'Black Box' trip meters record key events and parameters leading up to a trip to facilitate troubleshooting
Areas of use:
- Industrial pumps
- Driven pumps
- Industrial fans
- Conveyors / Handling
- Lifts / elevators
- Cranes and lifting devices
- Centrifuges
- Extruders
- Test benches
- Wind machines
Technical specifications:
Earth leakage current: >10 mA (all models)
Input power factor: 0.94
The enclosure classification of the product:
IP20 - other surfaces (Europe)
UL (c-UL) Open type (North America/Canada)
[Mounted in cabinet]: IP20 UL (c-UL) Open type (North America/Canada)
[Through panel mounting]: IP20 UL (c-UL) Open Type (North America/Canada)
Maximum switching frequency:
4 kHz up to a maximum of 12 kHz (downgrading may occur)
Output frequencies:
0...500 Hz at 4 kHz switching frequency
0...1000 Hz at 8 kHz switch frequency
0...1500 Hz at 12 kHz switching frequency
Operating humidity:
Maximum 85 % relative humidity at 40 °C non-condensing
Atmosphere: Non-flammable, non-corrosive and dust-free
Climatic conditions: Class 3k3, as defined in EN60721-3-3
Chemically active substances:
For the standard product, the compliance is with EN60271-3-3:
- Both classes 3C3 and 3C4 for hydrogen sulphide gas (H2S) at a concentration of 25 ppm for 1200 hours
- Both classes 3C1 (rural) and 3C2 (urban) for all 9 subjects defined in Table 4
Operating vibrations:
Test Fc according to EN60068-2-6
10 Hz <= f <= 57 Hz sinusoidal 0,075 mm amplitude
57 Hz<=f<=150 Hz sinusoidal 1 g
10 sweep cycles per axis on each of three mutually perpendicular axes
Standards:
The AC30 series drives listed on this page fulfil the following standards when installed in accordance with the relevant product manual:
- Overvoltage category: Overvoltage category III (number defining an impulse withstand level)
- Degree of contamination:
- Pollution degree II (non-conductive pollution, except temporary condensation) for control electronics
- Pollution degree III (dirty air classification) for parts mounted through the panel
- North America/Canada: Complies with UL508C and CSA22.2 #14 as an open type drive
- Europe: This product complies with the Low Voltage Directive 2006/95/EC
- EMC compatibility: CE marked in accordance with 2004/108/EC (EMC Directive)
- RoHS compliance: This product fulfils RoHS substance restrictions in accordance with EC Directive 2011/65/EU
- DNV Marine certification (0.75 to 75 kW): AC30 is suitable for use in marine and offshore applications
Designed to put you in control of your energy savings:
AC30 drives come complete with a host of features designed to simplify pump and fan control. In addition to quick installation and dedicated pump and fan macros, there are a number of other features dedicated to energy-saving pump and fan control, such as:
- Automatic belt break detection: Interactive monitoring of a fan's operating conditions allows the AC30 to detect a break in the drive belt between the fan and the motor, stop the motor and indicate an alarm condition.
- Catching a spinning load - "fly-catching": The fan control algorithms allow the AC30 to detect when a fan is spinning freely and regain control of it before it runs at the set speed.
- PID control: Multiple PID control loops can be programmed to monitor process variables and adjust the motor speed accordingly to achieve the desired variable setpoint.
- Intelligent pump profiles: Our advanced intelligent pump control algorithms monitor motor loads and provide users with a number of features specifically designed for pump control applications, such as:
- Dry running protection for the pump
- Flow detection (low and no flow)
- Detection of blocked pump
- Essential services (fire mode): If the fire mode is selected via digital input, the inverter runs continuously at the maximum programmed speed and ignores all other control signals and alarm conditions.
- Energy optimisation: Under constant speed conditions, the motor's power waveforms are optimised by the drive to reduce the motor's energy consumption without compromising performance.
- Skip frequencies: Up to 4 speed and frequency bands can be programmed into the AC30, to avoid resonance points on the fan, reducing vibration, wear and noise.
- Timed run function: 10 daily start/stop events can be programmed with different run rates over a 7-day period. This feature requires the optional Real Time Clock (RTC) and is ideal for applications where regular operating patterns or periods of activity need to be managed, for example in a production environment.
- Process timers: Multiple operation timers can be programmed to generate text messages on the drive keypad to coincide with process maintenance intervals.
Parker Drive Quicktool (PDQ) software:
PDQ is a programming, monitoring and diagnostic platform for AC30 series variable speed AC drives. Communication between the drive and the computer is via the built-in Ethernet port at the top of the drive. The software will automatically detect all AC30 devices connected to the Ethernet network. A number of wizards guide users through each aspect of using the software:
- Installation wizards guide the user through each step of commissioning a new drive or reconfiguring an existing drive; from selecting a motor from the supplied database or entering specific motor data, to configuring application macros or control logic to suit your specific application.
- Setup wizards allow technicians to monitor and adjust drive parameters either in a simple predefined environment or in an advanced mode that allows access to all parameters of the drive.
Parker Drive Developer (PDD) software:
PDD is a complete PLC programming tool for AC30 series drives, supporting all IEC 61131 languages, including ladder logic, structured text and function block diagrams. It provides access to all drive parameters and allows the user to create powerful AC30 drive solutions. It is also possible to create customised parameters and menus so that the user can describe the settings and status of the drive in the context of their own application. To help kick-start the development process, Parker provides pre-installed libraries with the following features:
- Basic speed control
- Fan and pump control
- Lindblock
- Hydraulic steering
- Cascaded pump control
- Communication between colleagues
| Weight | 4,5 kg |
|---|---|
| Effect | 1.1 kW |
| Tension | 400 V |
| Communication | Profibus |
| IP class | IP20 |
| EMC filter | Without filter |
| Size | D - AC30 |
| Reversal | Resolver |
Stabe offers world-leading electromechanics and pneumatics for industrial automation. We are proud to be the Electromechanical Technical Centre (EMTC) for Parker Hannifin and a certified distributor for Electromechanics in the Nordic region. More about Stabe
Payment against invoice, 30 days. Shipping cost will be added. All prices are shown in SEK. Stabe has an AAA credit rating. Terms of purchase.